7.1) Maintenance
The automation must undergo maintenance work on a regular basis,
in order to guarantee prolonged lifetime.
The maintenance operations must be performed in strict
compliance with the safety directions provided in this manual
and according to the applicable legislation and standards.
If other devices are present, follow the directions provided in the cor-
responding maintenance schedule differents from A60.
1. Is requires scheduled maintenance work every 6 months or
10.000manoeuvres(max.)afterpreviousmaintenance.
2. Disconnect all power supplies.
3. Check for any deterioration of the components which form the
automation, paying particular attention to erosion or oxidation
of the structural parts. Replace any parts which are below the
required standard.
4. Connect the electric power sources up again, and carry out the
testingandchecksstatedinParagraph“6Testing”.
!
This charter provides information about how to draw up a maintenance schedule, and the disposal of A60.
7) Maintenance and Disposal
7.2) Disposal
As in the case of installation, at the end of the product lifetime,
disposalproceduresmustbecarriedoutbyqualiedpersonnel.
This product comprises various types of materials, some of which
can be recycled while others must be disposed of. Check informa-
tion on the recycling and disposal procedures according to local
legislation for this product category.
!
Some parts of the product may contain pollutant or hazar-
dous substances; if disposed of into the environment these
may constitute a serious risk of damage to the environment
and public health.
As indicated by the symbol in gure
never dispose of this product in dome-
stic waste. Apply “classied waste col-
lection”proceduresfordisposalinaccor-
dance with local regulations or return the
product to the retailer when purchasing
a new model.
Localregulations mayenvisageseriousnesintheevent ofillegal
disposal of this product.
RADIO card
The control unit features a connector for plugging in an SM radio
card , which activates the inputs and allows the control unit to be
remote-controlled through a transmitter.
output1 STEP-BY-STEP
output 2 Open for pedestrians
output 3 Open
output 4 Close
8) Accessories
With the aim of improving products, Nice S.p.a reserves the right to modify technical characteristics at any time without notice, while main-
taining the same functionalities and intended use.
Alltechnicalcharacteristicsstatedrefertoanambienttemperatureof20°C(±5°C).
9) Technical characteristics
Model type: A60 A60/V1
Power 230Vac±10%,50-60Hz 120Vac±10%,50-60Hz
Maximum actuators power 300 W [1,3 A] 300 W [2,5 A]
Maximumashinglightpower 100W
Maximum frequency of operating cycles unlimited
Maximum time of continuous operation unlimited
Maximuncurrentaccessories(24Vac) 200mA
Maximun current phototest output 75 mA
Gateopenindicatormax.powerSCA(24Vac) 2W
Maximun electric lock power 12 Vac 15 VA
Workingtime from2,5to40sec.(from40to80sec.withTLM)
Pause time from 5 to 80 sec.
TRA opening delay time 0 or from 2.5 to 12 sec.
TRC closing delay time 0 or from 2.5 to 12 sec.
BALANCING manoeuvre times from 0 to 8 sec.
Force adjustment from 0 to 100 %
Operating temperature -20 ÷ 50 °C
Size 280 x 220 x 110 mm
Weight 1,9 kg
Protectionlevel IP55(containerundamaged)
EN