Appendix B
B-20
NJ/NX-series Database Connection CPU Units User’s Manual (W527)
B-3 Specifications
This section gives the specifications of the Database Connection CPU Units.
B-3-1 General Specifications
Refer to the following manual.
• NJ/NX-series CPU Unit Software User’s Manual (Cat. No. W501)
B-3-2 Performance Specifications
Refer to the following manual.
• NJ/NX-series CPU Unit Software User’s Manual (Cat. No. W501)
B-3-3 Function Specifications
Refer to the following manual.
• NJ/NX-series CPU Unit Software User’s Manual (Cat. No. W501)
• Common Specifications to NJ/NX-series CPU Units
Item NX701-20
NJ501-1
ï‚£
20
NJ501-4320 NJ101-20
Version 1.07
or earlier
Version 1.08
or later
Debugging
Data
tracing
Maximum
number of
simultaneous
data traces
4 4 2
*
2
*
2
*
* If the trace number is set to 2 or greater when executing a data trace related instruction, an error (Illegal Data
Position Specified) will occur for the instruction. ENO of the instruction will become FALSE.
• DB Connection Service Functionality
Refer to 1-2-1 DB Connection Service Specifications for detailed specifications of the DB Connection
Service.
Item
NX701-

20
NJ501-1
ï‚£
20
NJ501-4320
NJ101-

20
Maximum number of DB Connections
3
3
3
1
Supported DB* Oracle Supported Supported Supported Supported
SQL Server
Supported
Supported
Supported
Supported
DB2
Supported
Supported
Not supported
Supported
MySQL
Supported
Supported
Supported
Supported
Firebird
Supported
Supported
Not supported
Supported
PostgreSQL
Supported
Supported
Not supported
Supported
Number of DB
Map Variables
for which a
mapping can
be
connected*1 *
Oracle 30 30 15 15
SQL Server
60
60
15
15
DB2
30
30
N/A
15
MySQL
30
30
15
15
Firebird
15
15
N/A
15
PostgreSQL
30
30
N/A
15
Spool function
Spool capacity
2 MB
1 MB
1 MB
192 KB
*1 Even if the number of DB Map Variables has not reached the upper limit, the total number of members of
structures used as data type of DB Map Variables is 10,000 members max.
Note: The items marked with * (asterisk) were added or changed by version upgrades. Refer to B-4 Version
Information for the version upgrades.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron NX701-1620 and is the answer not in the manual?

Omron NX701-1620 Specifications

General IconGeneral
BrandOmron
ModelNX701-1620
CategoryController
LanguageEnglish

Related product manuals