Hunter-Pro Series
31
1.7. Hunter-Pro 8144 vs. Captain 8
Peripheral/Feature
Captain 8
Hunter-Pro 8144
System
Zones (incl. expanders)
16
144
Zone Doubling
Keypads
8
8
Partitions
4
16
Outputs
of which onboard
12
3
58
7
Logged events
of which non-volatile
160
128
500
250
Users
30
144
RFID tags
30
144
Expansion cards
EXP-PRO
-
I/O-8N/PS
1
17
I/O-16/PS
-
8
I/O-R
1
4
I/O-WN
Wireless zones
Key fobs
8
24
32
24
1.8. Technical Specs
Hunter-Pro 832/8144
Captain 8
Input voltage
14VAC/2A
Battery
12VDC, Up to 7.5 Ah
Operating
temperatures
(C)
Control panel: -10 ~ +50
LCD keypad: 0 ~ +50
LED keypad: -10 ~ +50
Protection
Single or double EOL resistor circuits
Continuous battery & telephone line monitoring
DC sirens EOL resistor protection
Humidity
75% (non-condensed)
PCB outputs
Relay: NO/NC 1A
Open collector: 4, 100mA
max
Bell/Siren outputs: 2 with
separate thermal fuses
protection
Open collector: 2, 100mA
max
Bell/Siren outputs: 1
Serial output: RS-232
Communication
Channels
PSTN: Telephone interface and communicator
GSM: GSM-200 transmitter
SMS: SMS-100 module (via PSTN)
Ethernet: net4pro TCP/IP module
Radio: TRV/TRU-100: long range VHF/UHF transmitters

Table of Contents