76
I/O-8N Zone expander's Relay output
Dial
I/O-8N
Dial
I/O-8N
Dial
I/O-8N
31
1
37
7
43
13
32
2
38
8
44
14
33
3
39
9
45
15
34
4
40
10
46
16
35
5
41
11
36
6
42
12
I/O-R Relay expander #1
I/O-R Relay expander #2
Dial
Relay
Dial
Relay
Dial
Relay
Dial
Relay
51
1
55
5
59
1
63
5
52
2
56
6
60
2
64
6
53
3
57
7
61
3
65
7
54
4
58
8
62
4
66
8
I/O-R Relay expander #3
I/O-R Relay expander #4
Dial
Relay
Dial
Relay
Dial
Relay
Dial
Relay
67
1
71
5
75
1
79
5
68
2
72
6
76
2
80
6
69
3
73
7
77
3
81
7
70
4
74
8
78
4
82
8
Send SMS system status
reports to user's phone #
Dial
Phone
Dial
Phone
91
1
93
3
92
2
94
4
14.2.1. Examples
Trip the ‘Ext. SIREN’ output:
Dial the panel’s phone number the panel picks up the call wait for the confirmation tone to
end dial the Master code wait for the confirmation tone to end
*
11
Deactivate relay #2 on I/O-R #2:
Dial the panel’s phone number the panel picks up the call wait for the confirmation tone to
end dial the Master code wait for the confirmation tone to end #60

Table of Contents

Other manuals for Pima Captain 8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pima Captain 8 and is the answer not in the manual?

Pima Captain 8 Specifications

General IconGeneral
BrandPima
ModelCaptain 8
CategorySecurity System
LanguageEnglish

Related product manuals