14 – Command Reference
Command Listing
59263-02 A 14-97
A
Set Config Threshold
Sets the port alarm threshold parameters by which the switch monitors port
performance and generates alarms. The changes you make with this command
are not retained when you reset or power cycle the switch unless you save them
using the Config Save command.
Authority Admin session and a Config Edit session
Syntax set config threshold
Initiates a configuration session by which to generate and log alarms for selected
events. The system displays each event, its triggers, and a sampling window one
line at a time and prompts you for a value. For each parameter, enter a new value
or press the Enter key to accept the current value shown in brackets. Table 14-23
describes the port alarm threshold parameters.
Table 14-23. Port Alarm Threshold Parameters
Parameter Description
Threshold Monitoring Enabled Master enable/disable parameter for all events.
Enables (True) or disables (False) the generation
of all enabled event alarms. The default is False.
CRCErrorsMonitoringEnabled
DecodeErrorsMonitoringEnabled
ISLMonitoringEnabled
LoginMonitoringEnabled
LogoutMonitoringEnabled
LOSMonitoringEnabled
The event type enable/disable parameter. Enables
(True) or disables (False) the generation of alarms
for each of the following events:
îš„ CRC errors
îš„ Decode errors
îš„ ISL connection count
îš„ Device login errors
îš„ Device logout errors
îš„ Loss-of-signal errors
Rising Trigger The event count above which a rising trigger alarm
is logged. The switch will not generate another ris-
ing trigger alarm for that event until the count
descends below the falling trigger and again
exceeds the rising trigger.
Falling Trigger The event count below which a falling trigger alarm
is logged. The switch will not generate another fall-
ing trigger alarm for that event until the count
exceeds the rising trigger and descends again
below the falling trigger.
Sample Window The time in seconds in which to count events.

Table of Contents

Other manuals for Qlogic SANbox 5800V Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Qlogic SANbox 5800V Series and is the answer not in the manual?

Qlogic SANbox 5800V Series Specifications

General IconGeneral
BrandQlogic
ModelSANbox 5800V Series
CategorySwitch
LanguageEnglish

Related product manuals