6 – Port Configuration
Displaying Port Information
6-4 59263-02 A
S
Port Threshold Alarm Configuration Parameters
Enter the Show Config Threshold command to display the port threshold alarm
parameters. These parameters determine the error thresholds at which the switch
issues alarms. Refer to Table 14-23 for a description of these parameters.
SANbox #> show config threshold
Configuration Name: default
------------
Threshold Configuration Information
-----------------------------------
ThresholdMonitoringEnabled False
CRCErrorsMonitoringEnabled True
RisingTrigger 25
FallingTrigger 1
SampleWindow 10
DecodeErrorsMonitoringEnabled True
RisingTrigger 25
FallingTrigger 0
SampleWindow 10
ISLMonitoringEnabled True
RisingTrigger 2
FallingTrigger 0
SampleWindow 10
LoginMonitoringEnabled True
RisingTrigger 5
FallingTrigger 1
SampleWindow 10
LogoutMonitoringEnabled True
RisingTrigger 5
FallingTrigger 1
SampleWindow 10
LOSMonitoringEnabled True
RisingTrigger 100
FallingTrigger 5
SampleWindow 10

Table of Contents

Other manuals for Qlogic SANbox 5800V Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Qlogic SANbox 5800V Series and is the answer not in the manual?

Qlogic SANbox 5800V Series Specifications

General IconGeneral
BrandQlogic
ModelSANbox 5800V Series
CategorySwitch
LanguageEnglish

Related product manuals