EasyManuals Logo
Home>Qlogic>Switch>SANbox 5800V Series

Qlogic SANbox 5800V Series Interface Guide

Qlogic SANbox 5800V Series
422 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #365 background imageLoading...
Page #365 background image
14 – Command Reference
Command Listing
59263-02 A 14-185
A
Show Testlog
Displays the contents of the diagnostic field test log file.
Authority None
Syntax show testlog
or
show test log
Examples The following is an example of the Show Testlog command:
SANbox #> show testlog
Queue: UID
Sequence Count: 17
Success Count: 10
Failed Count: 7
Records: 11
Record: 1 of 11
Time: Mon Sep 15 16:56:49 2008
Sequence Number: 1
Test: TEST_ONLINE (0x61)
Subtest: TEST_ONLINE (0x61)
Fault Code: DIAGS_ERR_INVALID_PORT_TYPE (0x14)
Loops: 0
Tx Blade/Asic/Port: 0/0/0
Record: 2 of 11
Time: Mon Sep 15 17:02:38 2008
Sequence Number: 3
Test: TEST_ONLINE (0x61)
Subtest: TEST_ONLINE (0x61)
Fault Code: DIAGS_ERR_INVALID_PORT_TYPE (0x14)
Loops: 0
Tx Blade/Asic/Port: 0/0/0
Record: 3 of 11
Time: Mon Sep 15 17:02:38 2008
Sequence Number: 2
Consecutive Passes: 1
.
.
.