1. Installation
Installation Requirements
Environment
Temperature/Humidity
Ranges:
Acceptable: 10C (50F) 15% to 27C (80.6F) 80%
Recommended (Office): 15C (59F) 30% to 25C (77F) 70%
Ambient Illumination: Less than 2000 lux (do not expose to direct sunlight).
Ventilation: 3 times/hr/person
1. Avoid areas that are exposed to sudden temperature changes. This includes:
• Areas directly exposed to cool air from an air conditioner.
• Areas directly exposed to heat from a heater.
2. Do not install this machine in an area where it will be exposed to corrosive gases.
3. Do not install the machine at locations over 2,500 m (8,125 ft.) above sea level.
4. Put the machine on a strong and level base. Inclination on any side should not exceed 5 mm.
5. Do not put the machine where it may be subjected to strong vibrations.
11