EasyManuals Logo
Home>SICK>Accessories>DT1000

SICK DT1000 User Manual

SICK DT1000
110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #69 background imageLoading...
Page #69 background image
Parameter Factory setting
LOW:
Input potential for the active state: low voltage
LOW
HIGH:
Input potential for the active state: high voltage
8.4 Device menu group
8.4.1 Switching the laser on and off
Switching the measurement and alignment laser on and off manually.
Parameter Factory setting
Alignment laser on:
Switching the alignment laser on/off
Off
Measurement laser on:
Switching the measurement laser on/off
On
8.4.2 Configuring the heater
Define the switch-on temperature of the front screen heater. Heating is activated when
the ambient temperature is below the defined switch-on temperature. The hysteresis is
fixed at 2 Kelvin.
The fogging and/or frosting of the front screen depends on the temperature, pressure
and air humidity. The dew point and/or the frost point can be calculated from these val‐
ues. To prevent the fogging and/or frosting of the front screen, the front screen heater
must be activated when the dew point or frost point is reached.
Parameter Factory setting
-20 °C ... +20 °C -10 °C
8.4.3 Defining the language
Selection of languages indicated on the display.
REFERENCE 8
8019329/12TZ/2019-03-28 | SICK O P E R A T I N G I N S T R U C T I O N S | DT1000 and DL1000
69
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK DT1000 and is the answer not in the manual?

SICK DT1000 Specifications

General IconGeneral
BrandSICK
ModelDT1000
CategoryAccessories
LanguageEnglish

Related product manuals