EasyManuals Logo
Home>SICK>Accessories>DT1000

SICK DT1000 User Manual

SICK DT1000
110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #74 background imageLoading...
Page #74 background image
8.5.6 Defining the RS-422 data protocol
Define the data protocol (only for continuous output, see "Protocol types and data for
continuous output", page 20).
Parameter Factory setting
CR/LF:
CarriageReturn/LineFeed as a separation symbol
CR/LF
STX/ETX:
STX/ETX protocol
8.5.7 Defining the distance value resolution for the RS-422 data transfer
Define the resolution of the distance measured value for continuous output. The dis‐
tance values are output in multiples of the set resolution. The resolution in request
mode is always 1 mm.
Parameter Factory setting
0.1:
0.1 mm
1 mm
1:
1 mm
10:
10 mm
100:
100 mm
Free input:
0.001 mm ... 1000 mm
8.5.8 Defining the speed value resolution for the RS-422 data transfer
Define the resolution of the speed measured value being output. The speed values are
output in multiples of the set resolution.
8 REFERENCE
74
O P E R A T I N G I N S T R U C T I O N S | DT1000 and DL1000 8019329/12TZ/2019-03-28 | SICK
Subject to change without notice

Table of Contents