EasyManuals Logo

Siemens SINAMICS V90 User Manual

Siemens SINAMICS V90
432 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
Fundamental safety instructions
1.2 Equipment damage due to electric fields or electrostatic discharge
SINAMICS V90, SIMOTICS S-1FL6
20 Operating Instructions, 04/2019, A5E36037884-007
1.2
Equipment damage due to electric fields or electrostatic discharge
Electrostatic sensitive devices (ESD) are individual components, integrated circuits, modules
or devices that may be damaged by either electric fields or electrostatic discharge.
NOTICE
Equipment damage due to electric fields or electrostatic discharge
Electric fields or electrostatic discharge can cause malfunctions through damaged
individual components, integrated circuits, modules or devices.
Only pack, store, transport and send electronic components, modules or devices in their
original packaging or in other suitable materials, e.g conductive foam rubber of
aluminum foil.
Only touch components, modules and devices when you are grounded by one of the
following methods:
Wearing an ESD wrist strap
Wearing ESD shoes or ESD grounding straps in ESD areas with conductive flooring
Only place electronic components, modules or devices on conductive surfaces (table
with ESD surface, conductive ESD foam, ESD packaging, ESD transport container).
1.3
Warranty and liability for application examples
Application examples are not binding and do not claim to be complete regarding
configuration, equipment or any eventuality which may arise. Application examples do not
represent specific customer solutions, but are only intended to provide support for typical
tasks.
As the user you yourself are responsible for ensuring that the products described are
operated correctly. Application examples do not relieve you of your responsibility for safe
handling when using, installing, operating and maintaining the equipment.

Table of Contents

Other manuals for Siemens SINAMICS V90

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS V90 and is the answer not in the manual?

Siemens SINAMICS V90 Specifications

General IconGeneral
Power Range0.05 kW to 7.0 kW
Protection ClassIP20
CommunicationUSS/Modbus RTU
FeedbackIncremental encoder
Input Voltage1AC 200 V to 240 V, 3AC 380 V to 480 V
Control ModesPosition, Speed, Torque
Operating Temperature0 °C to +40°C
Storage Temperature-40°C to +70°C
Relative Humidity5% to 95% (non-condensing)
AltitudeUp to 1000 m above sea level

Related product manuals