Mounting
3.2 Mounting the motor
SINAMICS V90, SIMOTICS S-1FL6
88 Operating Instructions, 04/2019, A5E36037884-007
3.1.3
Mounting the drive
Note
Screw tightening
Make sure you fix the screw to the terminal door of the drive after you have completed the
install
ation work.
Note
For the installation altitude lower than or equal to 2000
m above sea level, it is permissible to
connect the drive to any of the line supplies that are specified for it. For the installation
altitude higher than 2000
m and lower than 5000 m above see level, you must connect the
drive to any of the specified line supplies either via an isolating transformer or with a
grounded neutral point.
3.2
Mounting the motor
NOTICE
Damage to the encoder due to shocking
Shocks at the motor shaft end can cause an encoder damage.
•
Do not exert any shock at the shaft end.
For mounting conditions, see Technical data - servo motors (Page 68).