Diagnostics
11.2 List of faults and alarms
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2019, A5E36037884-007
387
11.2
List of faults and alarms
This section lists only common faults and alarms. To view the detailed information of all
faults and alarms, call the online help for an active fault/alarm in the SINAMICS V-
ASSISTANT engineering tool.
Fault list
Fault
Cause
Remedy
F1000: Internal software error
Reaction: OFF2
Acknowledgement: POWER
ON
An internal software error has occurred.
Evaluate fault buffer.
Carry out a POWER ON (power off/on) for
all components.
Upgrade firmware to later version.
Contact the Hotline.
Replace the Control Unit.
F1001: FloatingPoint excep-
tion
Reaction: OFF2
Acknowledgement: POWER
ON
An exception occurred during an operation
with the FloatingPoint data type.
Carry out a POWER ON (power off/on) for
all components.
Upgrade firmware to the latest version.
Contact the Hotline.
F1002: Internal software error
Reaction: OFF2
Acknowledgement:
IMMEDIATELY
An internal software error has occurred.
Carry out a POWER ON (power off/on) for
all components.
Upgrade firmware to the latest version.
Contact the Hotline.
F1003: Acknowledgement
delay when accessing the
memory
Reaction: OFF2
Acknowledgement:
IMMEDIATELY
A memory area was accessed that does
not return a "READY".
Carry out a POWER ON (power off/on).
Contact the Hotline.
F1015: Internal software error
Reaction: OFF2
Acknowledgement: POWER
ON
An internal software error has occurred.
Carry out a POWER ON (power off/on) for
all components.
Upgrade firmware to the latest version.
Contact the Hotline.

Table of Contents

Other manuals for Siemens SINAMICS V90

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS V90 and is the answer not in the manual?

Siemens SINAMICS V90 Specifications

General IconGeneral
Power Range0.05 kW to 7.0 kW
Protection ClassIP20
CommunicationUSS/Modbus RTU
FeedbackIncremental encoder
Input Voltage1AC 200 V to 240 V, 3AC 380 V to 480 V
Control ModesPosition, Speed, Torque
Operating Temperature0 °C to +40°C
Storage Temperature-40°C to +70°C
Relative Humidity5% to 95% (non-condensing)
AltitudeUp to 1000 m above sea level