Control functions
7.6 Speed control (S)
SINAMICS V90, SIMOTICS S-1FL6
258 Operating Instructions, 04/2019, A5E36037884-007
7.6.1.2
Speed control with fixed speed setpoint
Parameter settings
In the S mode, when at least one of the three digital input signals SPD1, SPD2 and SPD3 is
at high level, one of the following parameter values is used as speed setpoint.
Parameter
Range
Default
Unit
Description
Digital input
SPD3
SPD2
SPD1
p1001 -210000 to
210000
0 rpm Fixed speed setpoint 1 0 0 1
p1002 -210000 to
210000
0 rpm Fixed speed setpoint 2 0 1 0
p1003 -210000 to
210000
0 rpm Fixed speed setpoint 3 0 1 1
p1004 -210000 to
210000
0 rpm Fixed speed setpoint 4 1 0 0
p1005 -210000 to
210000
0 rpm Fixed speed setpoint 5 1 0 1
p1006 -210000 to
210000
0 rpm Fixed speed setpoint 6 1 1 0
p1007 -210000 to
210000
0 rpm Fixed speed setpoint 7 1 1 1
7.6.2
Direction and stop
Two digital input signals are used to control motor direction and run/stop.
CWE: clockwise enable
CCWE: counter-clockwise enable
The following table shows you in details:
Signal
Fixed torque setpoint
Analog torque setpoint
CCWE
CWE
+ polarity
- polarity
0 V
0
0
0
0
0
0
0
1
CW
CW
CCW
0
1
0
CCW
CCW
CW
0
1
1
0
0
0
0
Note
In S mode or T mode, when the servo motor is ready to run, signal CWE or CCWE is a must
to start running the motor.
For more information about signals
CWE and CCWE, refer to "DIs (Page 123)".

Table of Contents

Other manuals for Siemens SINAMICS V90

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS V90 and is the answer not in the manual?

Siemens SINAMICS V90 Specifications

General IconGeneral
Power Range0.05 kW to 7.0 kW
Protection ClassIP20
CommunicationUSS/Modbus RTU
FeedbackIncremental encoder
Input Voltage1AC 200 V to 240 V, 3AC 380 V to 480 V
Control ModesPosition, Speed, Torque
Operating Temperature0 °C to +40°C
Storage Temperature-40°C to +70°C
Relative Humidity5% to 95% (non-condensing)
AltitudeUp to 1000 m above sea level

Related product manuals