Scale parameters and functions
8.29 DR 32 Error messages
SIWAREX WP251
146 Manual, 12/2015, A5E37203357A
The individual error messages are presented and explained in detail in section "Messages"
(see Errors and messages (Page 163)). The following table is used only for breaking down
the individual messages into their message bits.
Table 8- 29 Assignment of data record 32
Variable
Note
Type
Length
(bytes)
RW
De-
fault
Mi
n.
Max.
Mod-
bus
regis-
ters
Data record number
Contains no. of the data record
USHORT
2
r
32
-
-
3500
Length
Data record length information
USHORT
2
r
32
-
-
3501
Application
Information on application to
which DR belongs
USHORT
2
r
105
-
-
3502
Version identifier
Current data record version in-
formation
USHORT
2
r
1
1
65535
3503
1000 Operating error There is at least one operating
error (=1 as long as an operating
error is present)
Bit_0 0 r 0 - - 3504
1001 Watchdog
Watchdog activated
Bit_1
0
r
0
-
-
3504
Reserve
Reserve
Bit_2
0
r
0
-
-
3504
1003 Checksum error (pa-
rameters)
Checksum error in parameters Bit_3 0 r 0 - - 3504
1004 Checksum error (pro-
gram)
Checksum error in program code Bit_4 0 r 0 - - 3504
Reserve
Reserve
Bit_5
0
r
0
-
-
3504
1006 Log book
Log book is full or defective
Bit_6
0
r
0
-
-
3504
1007 Application error
Wrong application loaded
Bit_7
1
r
0
-
-
3504
1102 ADC error
Analog-to-digital converter error
Bit_8
0
r
0
-
-
3504
Reserve
Reserve
Bit_9
0
r
0
-
-
3504
1104 Undervoltage Undervoltage at SENSE input Bit_10 0 r 0 - - 3504
1105 Overload
Overload
Bit_11
0
r
0
-
-
3504
1106 Underload
Underload
Bit_12
0
r
0
-
-
3504
1107 SecureDisplay failure Connection to SecureDisplay has
been interrupted
Bit_13 0 r 0 - - 3504
Reserve
Reserve
Bit_14
0
r
0
-
-
3504
Reserve
Reserve
Bit_15
1
r
0
-
-
3504
2000 Technological error At least one technology error
exists (group error)
Bit_0 0 r 0 - - 3505
2001 Timeout tare or zero
setting
Taring or zero setting is not pos-
sible because a standstill was not
reached during the standstill wait-
ing time
Bit_1 0 r 0 - - 3505
2002 Trace error The configured cycle for the trace
recording cannot be processed:
Reading is active or buffer is full;
recording is stopped
Bit_2 0 r 0 - - 3505

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIWAREX WP251 and is the answer not in the manual?

Siemens SIWAREX WP251 Specifications

General IconGeneral
BrandSiemens
ModelSIWAREX WP251
CategoryAccessories
LanguageEnglish

Related product manuals