Errors and messages
9.6 Operating errors
SIWAREX WP251
172 Manual, 12/2015, A5E37203357A
Data and command errors - Additional information
Additional information is available for most data/command errors. The cause of the error is
described in detail with this information. If a data/command error bit is set, the additional
information is also filled accordingly. Thus, the error bits and the additional information must
be evaluated together in the program to identify the exact cause of the error.
If additional information not listed above appears for a data/operating error bit, it is a
parameter ID. This defines the exact parameter that caused the error.
The following table presents the association between the parameter and parameter ID.
Standstill 2 - range 3 2154
Calibration digits 0 (measured)
Calibration digits 1 (measured)
Calibration digits 2 (measured)
Frequency low pass filter 1
Order no. low pass filter 1
Automatic zero tracking in dosing cycle 3 3247
Max. waiting time for standstill 1
Weight simulation allowed
Negative zeroing limit (initial zeroing)