USO RESTRITO
Settings Relating to Function Links 359
Chapter
19
Switcher
Setup
6
To select for each bus whether the GPI link setting is
enabled or disabled, select the bus to which the setting
applies.
7
In the <Bus> group, select any of the following.
Enable: Enables the GPI link setting for the selected
bus.
Disable: Disables the GPI link setting for the selected
bus.
All Enable: Enables the GPI link setting for all buses.
Setting the delay value
1
In the Engineering Setup >Switcher >Link >GPI Link
>GPI Link Adjust menu (7336.5), select the output
port for which you want to set the delay value, and the
corresponding delay value.
No.
Parameter
Adjustment
1
GPI Port
GPI output port to be configured
5
Delay
Delay value for the output port
2
Press [Delay Set].
Setting the operation mode when selecting
M/E reentry inputs
When you select a reentry signal in the cross-point control
block of an M/E block (upstream M/E block), the output of
the upstream M/E block is read in. You can set the system
so that when a GPI link is set for the cross-point selected
on the A bus
1)
of the upstream M/E block this triggers the
GPI output.
In the Engineering Setup >Switcher >Link >GPI Link
menu (7336.4), set [Re-Entry Enable] to On or Off.
When set to On, the GPI is executed upstream.
1) When the bus toggle is set to Off, the applicable bus depends on the
position of the fader lever.
Notes
For reentry, “upstream” applies to a single stage only.
This setting is common to all GPI output ports.
GPI output execution on the upstream M/E block is only
possible on buses for which the GPI link is set to
[Enable] in the GPI Link Adjust menu.
GPI outputs are executed when reentry signals are
selected under the following conditions.
-
When selected using buttons in cross-point control
block
-
When selected by macro execution
-
When selected on the AUX bus remote panel
Setting Links between M/E Banks
The operations for which you can link two M/E banks are
as follows.
Transition execution (auto transition, cut, and fader lever
operation)
Next transition selection
Transition type selection
1
In the Engineering Setup >Switcher >Link >M/E Link
menu (7336.6), specify the link number to set.
2
In the <M/E Select> group, select [Master M/E] (link
source).
3
Select the M/E or PGM/PST link source, then press
[M/E Set].
4
In the <M/E Select> group, select [Linked M/E] (link
destination).
5
Select the M/E or PGM/PST bank you want to be the
link destination, then press [M/E Set].
To link the banks not only for transition execution
but also for the other operations
Press [Transition Only], turning it off.
To release a link
Use the same operation as in step 1 to select the link
number for which you want to release the link setting, then
press [Clear].
Making a Link Setting for Key
Transition
The operations for which you can link two banks are the
following independent key transition operations.
Auto transition
Turning the key on or off
1
In the Engineering Setup >Switcher >Link >Key
Transition Link menu (7336.7), specify the link
number to set.
2
In the <Key Select> group, select [Master Key] (link
source).
3
Select the key you want to be the link source, then
press [Key Set].
4
In the <Key Select> group, select [Linked Key] (link
destination).

Table of Contents

Other manuals for Sony ICP-6530

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sony ICP-6530 and is the answer not in the manual?

Sony ICP-6530 Specifications

General IconGeneral
BrandSony
ModelICP-6530
CategorySwitch
LanguageEnglish

Related product manuals