5-34 OM 25-3503 us – Edition 4.1 * * 2503_3503b530.fm
Maintenance
Putting into operation again
☞ Remove the grease from the piston rods.
☞ Install or connect the battery.
☞ Remove the seals from the exhaust pipe and the air filter intake.
☞ Check the condition of the air filter cartridges and replace them if necessary.
☞ If the machine was out of service for over 6 months, change the oil in the gearbox,
engine and other units.
☞ Also replace hydraulic oil filters (return and breather filters) if the machine has been out
of service for over 6 months.
☞ Lubricate the machine according to the lubrication plan.
☞ Add a little engine oil.
☞ Check the levels.
☞ Remove the cutoff solenoid from the engine.
☞ Let the engine run 10 seconds.
☞ Wait 1 minute.
☞ Let the engine run 10 seconds again.
☞ Fit the cutoff solenoid back on again.
☞ Start the engine and let it run without any load.