6-6 OM 25-3503 us – Edition 4.1 * * 2503_3503b610.fm
Technical datac
6.4 Electrical system
Fuse box in cabin
6.5 Noise levels
Information!
Measurements performed on asphalted surface.
Fig. 304: Fuse box
2
1
3
4
11
10
9
5
6 7
8
Fuse no.
Rated current
(A)
Protected circuit
110
Switch assignment, indicator lights and indicators,
engine relays
2 15 Lights, boom, roof lights
3 10 12V/15 cabin
4 15 Heating, horn
5 10 Valves, travel signal
6 10 Window wiper, cabin
7 10 Alternator
8 15 Spare
910
Rotating beacon, radio, 12 V power outlet, antitheft
protection
10 15 Socket
11 10 Spare
Sound power level 2503 3503
Sound power level (L
WA
)
1
up to AG02452
1. ISO 6395 (EC Directives 2000/14/EC and 2005/88/EC)
93 dB (A)
Sound power level (L
WA
)
1
from AG02453 94 dB(A) 95 dB(A)
Uncertainty factor (K
PA
)
2
2. EN ISO 4871 (EC Directives 2000/14/EC and 2005/88/EC)
0.8 dB(A) 0.8 dB(A)
Operator-perceived sound pressure level (L
PA
)
3
3. ISO 6394 (EC Directives 84/532/EEC, 89/514/EEC, 95/27/EEC)
d 75dB (A) d 76dB (A)