61
www.amcelettronica.com
KX series v.1.70
PROGRAMS MENU
The control unit has 4 programs that can be named with the following characteristics:
- Can be independently armed/disarmed
- Can be freely associated to users
- can be freely associated to arming/disarming timers
- can have independently programmable arming times
- can be clustered in activation groups, which can also be named
programs menu: partials names
The system for assigning names to the partials is identical to the one used for inputs and outputs. The vocabulary used is the same.
programs menu: partial zones (assigning zones to partials)
It is possible to associate any zones to each partial. It is possible also have the same inputs associated to several partials.
Go to the programs menu and select PARTIAL ZONE 1. Using the vertical arrow keys, select the desired partial and press enter to
associate the zones (fig. below)
The figure shows the association of the first 3 zones to partial 1.
The zone assigning method is the same as the one already mentioned for other menus (inputs, outputs)
- Use the RIGHT and LEFT arrows to select the desired input, then press ENTER again
- Enable it by pressing CANCEL when the cursor flashes
- Press CANCEL again to delete
- At the end, confirm with ENTER
programs menu: exit times
For each partial there are different output time.
When several partials are armed at the same time, the longest time is taken into consideration.
In figure on, an output time of 30 seconds was associated.
P01-Program Nr.01
V - Edit
P01-Program Nr.01
009 123 076 000
[01] program 01
[Sec.] 30
GROUPS MENU
It is possible create the arming scenarios (group), that include several partials. There are 4 scenarios, they can be armed by using the
G1 - 2 - 3 - 4 keys from keypad. In the control unit menu they are called groups and some partial can be placed in arming group.
It is possible to use the group for quick arm procedure.
Note: the numbering of the groups is only an example, the program default is:
G1 = Total (all partials) - G2 = Perimeter (partials 1 - 2) - G3 = Night (partials 3 - 4) G4 = no programming
As in the figure, the system for assigning names to the GROUPS is always the same, including the vocabulary.
Fig 1 shows the change menu for the name, fig 2 shows the method (shown previously) to assign the names (the 3 digit numbers
indicate the vocabulary, see page 34, for a total of 4 words for each name)
groups menu: groups (associate partials to groups)
associate partials to groups: In the figure at Group 1 (perimeter) are associated the first 3 partial.
G01/Prg 12345678
Perimeter
- The groups are selected using the vertical arrow keys.
- RIGHT and LEFT arrows to select the partial, then press ENTER
- Enable it by pressing CANCEL when the cursor flashes
- Press CANCEL again to delete
- At the end, confirm with ENTER