77
www.amcelettronica.com
KX series v.1.70
This parameter indicates after how many hours the system must regularly inform the user that the life test result is successful and that
therefore the system system works properly. (the value to be inserted is expressed in hours)
Press ENTER, press CANCEL to delete the current value. Set the new value and press ENTER to confirm. Can be set from 0 to 240.
Note: the default value is 0 = disabled
It is possible set the hour of start the life test.
eg. every 24hours at 04:00 AM
OTHER PARAMETERS: EN50131 SETTINGS
EN50131 sEttiNgs: ENablE 50131
This parameter is an automatic configurator for the set up of the control unit in order to be in compliance with EN 50131 - 1 and
EN 50131 - 3. When the function is activated the following parameters are changed:
- input and output times set to 45" (only if set higher)
- all inputs configured as double balancing
- masking of the display of the system status. The system status will only appear in the first 30" after arming and disarming.
- activation of all arming blocks for conditions other than the standard ones (open zones, errors, tampers, etc.)
Press ENTER to set the value (0=disabled, 1=enabled) Confirm with ENTER
This parameter enable the masking from the display of the system status. The system status will only appear in the first 30" after
arming and disarming. Press ENTER to set the value (0=disabled, 1=enabled) Confirm with ENTER
EN50131 sEttiNgs: visual.status
This parameter is the time that elapses between the no power notification, which is instantaneous, and the remote communication
through the GSM communicator (SMS, CID). Press ENTER and set the value (value can be set from 0 to 240 sec.) Confirm with ENTER
default: 0 seconds, immediate call
EN50131 sEttiNgs: No 220 (miN)
EN50131 sEttiNgs EN 50131: sElf-ExclusioN
It determines the maximum number of consecutive alarms/tampers for zone after which the system will automatically disable it for
that single Arming/Disarming. (after disarm the exclusion reset)
Press CANCEL to delete the current value. Set the new value and press ENTER to confirm. It can be set (from 1 to 10) Default = 5
OTHER PARAMETERS: LIFE TEST
With this parameter the control unit can be armed without using your personal code. The settings of “ Quick Arming “ function are
related to the last user available (32th) for link the partition and groups.
Press ENTER and press 1 to enable press 0 to disable (is important to ready programmed linking programs on user 32)
OTHER PARAMETERS: QUICK ARMING
This parameter activates the masking of the not ready zones in LCD. In normal mode when there are zones not ready and/or troubles,
the LCD displays such zones/troubles. Press ENTER to set the value (0=disabled, 1=enabled) Confirm with ENTER
EN50131 sEttiNgs: visual.zoNEs
With this parameter put the control unit in maintenance mode. This condition means the system, even in the presence of alarms,
tampers, errors, etc., does not activate the siren or remote communications.
When the control unit is in maintenance mode it will show on the display.
Press ENTER set 1 to enable or 0 to disable
OTHER PARAMETERS: MAINTENANCE
* MAINTENANCE! *
14:30:15
This parameter is a regulator of current charge for battery. In default the current of charge is 300mA. It is possible increase the
current to 450mA. Press enter and use the CANCEL key for increase.
EN50131 sEttiNgs: chargE battEry
Other Parameter
Battery charge
Other Parameter
Battery charge