Determining Whether a Card has Failed
The ASR 5500 has several ways to indicate an application card failure. The first indicator is that the Status
LED on the System Status Card (SSC) turns red to indicate the failure of a chassis component. Another
indicator is the Run/Fail LED on an application card is red or turns off if that card has a problem.
If you see either of these indicators, you can determine the nature of the problem by using the CLI or checking
the Simple Network Management Protocol (SNMP) traps that may have been generated.
show card diag Command
Execute the show card diag slot_# command from the CLI in Exec mode. slot_# is the chassis slot number
in which the particular card that you wish to monitor is installed. The following is a sample output for this
command to monitor the card in chassis slot 5:
[local]asr5500# show card diag 5
Card 5:
Counters:
Successful Warm Boots : 0
(last at Friday July 29 13:45:58 us-eastern 2011)
Successful Cold Boots : 2
(last at Friday July 29 13:46:20 us-eastern 2011)
Total Boot Attempts : 1
In Service Date : Fri Jul 29 13:50:58 2011
Status:
IDEEPROM Magic Number : Good
Boot Mode : Normal
Card Diagnostics : Pass
Current Failure : None
Last Failure : None
Card Usable : Yes
Current Environment:
Temp: DDR-C0D0 : 30.00 C (limit 100.00 C)
Temp: DDR-C0D1 : 30.00 C (limit 100.00 C)
Temp: DDR-C1D0 : 30.00 C (limit 100.00 C)
Temp: DDR-C1D1 : 30.00 C (limit 100.00 C)
Temp: DDR-C2D0 : 30.00 C (limit 100.00 C)
Temp: DDR-C2D1 : 30.00 C (limit 100.00 C)
Temp: CPU-N0C0 : 30.00 C (limit 101.00 C)
Temp: CPU-N0C1 : 30.00 C (limit 101.00 C)
Temp: CPU-N0C2 : 30.00 C (limit 101.00 C)
Temp: CPU-N0C3 : 30.00 C (limit 101.00 C)
Temp: CPU-N0C4 : 30.00 C (limit 101.00 C)
Temp: CPU-N0C5 : 30.00 C (limit 101.00 C)
Temp: IOH : 35.00 C (limit 110.00 C)
Temp: NP4 #0 : 35.00 C (limit 115.00 C)
Temp: NP4 #1 : 35.00 C (limit 115.00 C)
Temp: NP4 #2 : 35.00 C (limit 115.00 C)
Temp: NP4 #3 : 35.00 C (limit 115.00 C)
Temp: LM94 : 0.00 C
Temp: Petra1 : 35.00 C (limit 100.00 C)
Temp: Petra2 : 35.00 C (limit 100.00 C)
Temp: Upper-right : 27.50 C (limit 85.00 C)
Temp: Petra3 : 35.00 C (limit 100.00 C)
Temp: Petra4 : 35.00 C (limit 100.00 C)
Temp: Mid-right : 27.50 C (limit 85.00 C)
Temp: MDF : 25.00 C (limit 80.00 C)
Temp: Lower-right : 22.50 C (limit 75.00 C)
Temp: Upper-left : 27.50 C (limit 85.00 C)
Temp: Lower-left : 27.50 C (limit 85.00 C)
Temp: DC1 : 27.50 C (limit 85.00 C)
Temp: DC2 : 27.50 C (limit 85.00 C)
Temp: F600 #1 : 0.00 C
Temp: F600 #2 : 0.00 C
ASR 5500 Installation Guide
138
Replaceable Components
Determining Whether a Card has Failed

Table of Contents

Other manuals for Cisco ASR 5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ASR 5500 and is the answer not in the manual?

Cisco ASR 5500 Specifications

General IconGeneral
BrandCisco
ModelASR 5500
CategoryNetwork Router
LanguageEnglish

Related product manuals