110 Configuration: Disk Groups and Virtual Disks
To change the segment size of a virtual disk:
1
In the AMW, select the
Logical
tab and select a virtual disk.
2
Select
Virtual Disk

Change

Segment Size
.
3
Select the required segment size.
A message prompts you to confirm the selected segment size.
4
Click
Yes
.
The segment size modification operation begins. The virtual disk icon in
the
Logical
pane shows an
Operation in Progress
status while the
operation is taking place.
NOTE: To view the progress or change the priority of the modification operation,
select a virtual disk in the disk group, and select Virtual Disk

Change

Modification Priority.
Changing the I/O Type
You can specify the virtual disk I/O characteristics for the virtual disks that
you are defining as part of the storage array configuration. The expected I/O
characteristics of the virtual disk is used by the system to indicate an
applicable default virtual disk segment size and dynamic cache read prefetch
setting. For more information about the Automatic Configuration Wizard,
see the PowerVault Modular Disk Storage Manager online help topics.
NOTE: The dynamic cache read prefetch setting can be changed later by selecting
Virtual Disk

Change

Cache Settings. You can change the segment size later by
selecting Virtual Disk

Change

Segment Size.
The I/O characteristic types shown below are only presented during the create
virtual disk process.
When you choose one of the virtual disk I/O characteristics, the
corresponding dynamic cache prefetch setting and segment size that are
typically well suited for expected I/O patterns are populated in the Dynamic
cache read prefetch field and the Segment size field.
book.book Page 110 Friday, September 23, 2011 2:46 PM

Table of Contents

Other manuals for Dell POWERVAULT MD3600F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell POWERVAULT MD3600F and is the answer not in the manual?

Dell POWERVAULT MD3600F Specifications

General IconGeneral
HDD speed15000 RPM
RAID levels0, 1, 5, 6, 10
Data transfer rate8 Gbit/s
Storage drive size3.5 \
Storage drive capacity600 GB
Storage drive interfaceSerial Attached SCSI (SAS)
Storage drives installedYes
Installed storage drive typeHDD
Supported storage drive typesHDD & SSD
Total installed storage capacity3.6 TB
Maximum supported storage capacity36 TB
Number of storage drives installed6
Number of storage drives supported12
Chassis type-
Product colorGray
LED indicatorsPower, Status
AC input voltage90-264 V
AC input frequency47/63 Hz
Number of power supply units1
Power supply unit (PSU) capacity600 W
Operating altitude-16 - 3048 m
Operating temperature (T-T)10 - 35 °C
Operating relative humidity (H-H)20 - 80 %
Weight and Dimensions IconWeight and Dimensions
Depth561 mm
Width446.3 mm
Height86.8 mm
Weight29300 g