130 Configuration: Disk Groups and Virtual Disks
ownership of the target virtual disk is restored to its preferred RAID controller
module. If ownership of the source virtual disk is changed during the virtual
disk copy, ownership of the target virtual disk is also changed. Under certain
operating system environments, it may be necessary to reconfigure the multi-
path driver before an I/O path can be used.
To change the RAID controller module ownership of a disk group:
1
In the AMW, select the
Logical
tab and select a disk group.
2
Select
Disk Group

Change

Ownership/Preferred Path
.
3
Select the appropriate RAID controller module slot and click
Yes
to
confirm the selection.
CAUTION: Possible loss of data access– Changing ownership at the disk group
level causes every virtual disk in that disk group to transfer to the other RAID
controller module and use the new I/O path. If you do not want to set every virtual
disk to the new path, change ownership at the virtual disk level instead.
The ownership of the disk group is changed. I/O to the disk group is now
directed through this I/O path.
NOTE: The disk group may not use the new I/O path until the multi-path driver
reconfigures and recognizes the new path. This action usually takes less than
5 minutes.
Changing the RAID Level of a Disk Group
Changing the RAID level of a disk group changes the RAID levels of every
virtual disk that comprises the disk group. Performance may be slightly
affected during the operation.
Guidelines to change the RAID level of a disk group:
You cannot cancel this operation after it begins.
The disk group must be in
Optimal
status before you can perform
this operation.
Your data remains available during this operation.
If you do not have enough capacity in the disk group to convert to the new
RAID level, an error message is displayed, and the operation does not
continue. If you have unassigned physical disks, use the
Disk Group

Add Free Capacity
(Physical Disks) option to add additional capacity to
the disk group. Then retry the operation.
To change the RAID level of a disk group:
book.book Page 130 Friday, September 23, 2011 2:46 PM

Table of Contents

Other manuals for Dell POWERVAULT MD3600F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell POWERVAULT MD3600F and is the answer not in the manual?

Dell POWERVAULT MD3600F Specifications

General IconGeneral
HDD speed15000 RPM
RAID levels0, 1, 5, 6, 10
Data transfer rate8 Gbit/s
Storage drive size3.5 \
Storage drive capacity600 GB
Storage drive interfaceSerial Attached SCSI (SAS)
Storage drives installedYes
Installed storage drive typeHDD
Supported storage drive typesHDD & SSD
Total installed storage capacity3.6 TB
Maximum supported storage capacity36 TB
Number of storage drives installed6
Number of storage drives supported12
Chassis type-
Product colorGray
LED indicatorsPower, Status
AC input voltage90-264 V
AC input frequency47/63 Hz
Number of power supply units1
Power supply unit (PSU) capacity600 W
Operating altitude-16 - 3048 m
Operating temperature (T-T)10 - 35 °C
Operating relative humidity (H-H)20 - 80 %
Weight and Dimensions IconWeight and Dimensions
Depth561 mm
Width446.3 mm
Height86.8 mm
Weight29300 g