Configuration: About Your Host 93
Creating a Host Group
1
In the AMW, select the
Mappings
tab.
2
In the
Topology
pane, select the storage array or the
Default Group
.
3
Perform one of the following actions:
Select
Mappings

Define

Host Group
Right-click the storage array or the
Default Group,
and select
Define

Host Group
from the pop-up menu.
4
Type the name of the new host group in
Enter new host group name
.
5
Select the appropriate hosts in the
Select hosts to add
area.
6
Click
Add
.
NOTE: To remove hosts, select the hosts in the Hosts in group area, and click
Remove.
7
Click
OK
.
The host group is added to the storage array.
Adding a Host to a Host Group
You can add a host to an existing host group or a new host group using the
Define Host Wizard. For more information, see "Defining a Host" on
page 90.
You can also move a host to a different host group. For more information, see
"Moving a Host to a Different Host Group" on page 94.
Removing a Host From a Host Group
You can remove a host from the Topology pane on the Mappings tab of the
Array Management Window. For more information, see "Removing a Host
Group" on page 94.
book.book Page 93 Friday, September 23, 2011 2:46 PM

Table of Contents

Other manuals for Dell POWERVAULT MD3600F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell POWERVAULT MD3600F and is the answer not in the manual?

Dell POWERVAULT MD3600F Specifications

General IconGeneral
HDD speed15000 RPM
RAID levels0, 1, 5, 6, 10
Data transfer rate8 Gbit/s
Storage drive size3.5 \
Storage drive capacity600 GB
Storage drive interfaceSerial Attached SCSI (SAS)
Storage drives installedYes
Installed storage drive typeHDD
Supported storage drive typesHDD & SSD
Total installed storage capacity3.6 TB
Maximum supported storage capacity36 TB
Number of storage drives installed6
Number of storage drives supported12
Chassis type-
Product colorGray
LED indicatorsPower, Status
AC input voltage90-264 V
AC input frequency47/63 Hz
Number of power supply units1
Power supply unit (PSU) capacity600 W
Operating altitude-16 - 3048 m
Operating temperature (T-T)10 - 35 °C
Operating relative humidity (H-H)20 - 80 %
Weight and Dimensions IconWeight and Dimensions
Depth561 mm
Width446.3 mm
Height86.8 mm
Weight29300 g