AT commands I/O settings commands
Digi XBee3® 802.15.4 RF Module User Guide
114
Bit I/O line
13
DIO7/CTS
14 UART_DOUT
15 DIO15
16 N/A
17 N/A
18 N/A
19 N/A
Parameter range
0 - 0xFFFFF (bit field)
Default
0xFFFF
Example
Sending the command ATPR 6F turn bits 0, 1, 2, 3, 5 and 6 ON, and bits 4 and 7 OFF. The binary
equivalent of 0x6F is 01101111. Bit 0 is the right-most digit in the binary bit field.
PD command
See PR command for the bit mappings.
Parameter range
Through-hole: 0 - 0xFFFF
SMT/MMT: 0 - 0xFFFFF
Default
0xFFFF
M0 command
The duty cycle of the PWM0 line (Micro pin 7/SMT pin 7).
If IA (I/O Input Address) is set correctly and P0 command is configured as PWM0 output, incoming AD0
samples automatically modify the PWM0 value. See PT (PWM Output Timeout).
To configure the duty cycle of PWM0:
1. Enable PWM0 output (P0 = 2).
2. Change M0 to the desired value.
3. Apply settings (use CN or AC).
The PWM period is 64 µs and there are 0x03FF (1023 decimal) steps within this period. When M0 = 0
(0% PWM), 0x01FF (50% PWM), 0x03FF (100% PWM), and so forth.
Parameter range
0 - 0x3FF