Modes Command mode
Digi XBee3® 802.15.4 RF Module User Guide
30
The preceding example changes NI command to My XBee.
Multiple AT commands
You can send multiple AT commands at a time when they are separated by a comma in Command
mode; for example,ATNIMy XBee,AC<cr>.
The preceding example changes theNI (Node Identifier) to My XBeeand makes the setting active
through AC (Apply Changes).
Parameter format
Refer to the list of AT commands for the format of individual AT command parameters. Valid formats
for hexidecimal values include with or without a leading0xfor exampleFFFFor0xFFFF.
Response to AT commands
When using AT commands to set parameters the XBee3 802.15.4 RF Module responds with OK<cr> if
successful and ERROR<cr> if not.
Apply command changes
Any changes you make to the configuration command registers using AT commands do not take effect
until you apply the changes. For example, if you send theBDcommand to change the baud rate, the
actual baud rate does not change until you apply the changes. To apply changes:
1. Send AC (Apply Changes).
2. Send WR command.
or:
3. Exit Command mode.
Make command changes permanent
Send a WR command command to save the changes. WR writes parameter values to non-volatile
memory so that parameter modifications persist through subsequent resets.
Send as RE command to wipe settings saved using WR back to their factory defaults, or custom
defaults if you have set any.
Note You still have to use WR to save the changes enacted with RE.
Exit Command mode
1. Send CN command followed by a carriage return.
or: