EasyManuals Logo
Home>Digi>Control Unit>XBee3 802.15.4

Digi XBee3 802.15.4 User Manual

Digi XBee3 802.15.4
185 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #119 background imageLoading...
Page #119 background image
AT commands I/O line passing commands
Digi XBee3® 802.15.4 RF Module User Guide
119
Parameter range
1 0xFF
Default
1
IO command
Sets digital output levels. This allows DIO lines setup as outputs to be changed through Command
mode.
Parameter range
8-bit bit map; each bit represents the level of an I/O line set up as an output
Default
N/A
I/O line passing commands
The following AT commands are I/O line passing commands.
IA (I/O Input Address)
The source address of the device to which outputs are bound.
To disable I/O line passing, set all bytes to 0xFF.
To allow any I/O packet addressed to this device (including broadcasts) to change the outputs, set IA
to 0xFFFF.
Parameter range
0 - 0xFFFF FFFF FFFF FFFF
Default
0xFFFFFFFFFFFFFFFF (I/O line passing disabled)
IU command
IU disables or enables I/O APIUART output when line passing is enabled if the received sample has a
source address that matches IA (I/O Input Address) or if IA is set to 0xFFFF.
Note To enable API output, you must set APcommand to an APImode (AP = 1 or 2).
Parameter range
0 - 1
Parameter Description
0 Disabled
1 Enabled

Table of Contents