Frame descriptions RX Packet: 64-bit Address frame - 0x80
Digi XBee3® 802.15.4 RF Module User Guide
145
RX Packet: 64-bit Address frame - 0x80
Description
When a device configured with legacy API Rx Indicator (AO = 2) receives an RF data packet from a
device configured to use 64-bit addressing (MY = 0xFFFE), it sends this frame out the serial interface.
Format
The following table provides the contents of the frame. For details on frame structure, see API frame
format.
Frame
data
fields Offset Description
Frame
type
3 0x80
64-bit
source
address
4-11
The sender's 64-bit address.
RSSI
12
Received Signal Strength Indicator. The Hexadecimal equivalent of (-dBm)
value. For example if RX signal strength is -40 dBm, then 0x28 (40 decimal) is
returned.
Options
13
Bit field:
0 = [reserved].
1 = Packet was a broadcast packet.
2 = Packet was broadcast across all PANs.
3-7 = [reserved].
Received
data
14-n
The RF data that the device receives.