3-1
The radiotelephone and the DSC are set up through “RT SETUP” and “DSC
SETUP“ menus respectively. Either No.1 controller or No.2 controller can be used for
setting up. The DIP switch on T-CPU board is set according to the system
configuration.
This chapter also describes how to enter MMSI.
3.1 MMSI Number, Model and Group ID
MMSI and Model are registered through “EEROM clear” menu and Group ID through
“Message file entry” menu.
3.1.1 MMSI Number (MMSI CLEAR)
The MMSI is changed by following the procedure below.
1. Turn on the system and then press “S1 (NMI SW)” on T-CPU board. “EEROM
clear” appears.
2. Enter password ([x][x][x][x][x][x]).
3. Move the cursor to “MMSI CLEAR” and then press [ENT].
4. Enter MMSI of own ship and then press [ENT].
5. Turn off the system and turn it on again.