1.1.2 Block Functions
Here is an example referring to the setting of a digital signal (Ramp output = 0) and of an analog signal (Speed
ref 1).
Digital signal
Let’s consider a section of the Ramp Block.
In Ramp funct src menu, the source Ramp output = 0 allows the output of the RampBlock to be set to zero. By
editing (for example via the keypad by pressing
enter) the source Ramp output = 0, the pick-list of the possible
signal sources of control is displayed.
The selected signal on the source, will be enable the
Ramp output = 0 function.
The Ramp funct cfg menu configures the block parameters. The Ramp funct mon display the signal state.
RAMP CONFIG / Ramp function /
Ramp funct src
Ramp output=0
…………
The following commands are available in
the source Ramp output=0 (it is standard connected to Null):
One it connects the signal to One, Active
Null it connects the signal to Zero, Non-active
DI 1 monitor it connects the signal to the standard digi
tal input 1, being active or non-active is a
function of the digital input state
………… …………
DI 0X monitor it connects the signal to the expanded dgt 0 input
B0 W0 decomp it connects the signal to a digital bit de
rived from a complete word. For more
detail on this feature, refer to the 2.6.6
‘chapter.
………… …………
RAMP CONFIG / Ramp function / Ramp funct cfg
Ramp shape
…………
The Ramp shape configuration allows to select the Ramp:
Linear
it sets the Linear Ramp
S-Shaped
it sets the S Ramp
RAMP CONFIG / Ramp function / Ramp funct mon
Ramp out mon
………
It is possible to monitor:
Ramp out mon
Output Ramp monitor
Ramp cmds mon
Ramp Block command monitor
………… …………
NOTE! The points …………, refer to other possibilities parameters in the menus.