AV-300i Version 2 Users Guide
—————— Function Description ——————
Ch.1
89
Ramp output=0
Ramp freeze
Ramp setpoint
Ramp input=0
Ramp out mon
Ramp shape Ramp out enable
Ramp function
RAMP CONFIG Ramp funct src
Ramp input=0 Selection of the source Ramp imput=0
Ramp output=0 Selection of the source Ramp output=0
Ramp freeze Selection of the source Ramp freeze=0
Ramp funct cfg
Ramp out enable Ramp enabling
Ramp shape Ramp selection. Linear or S-shaped ramp
Ramp funct mon
Ramp out mon Ramp output monitor
Ramp acc state Ramp state. 1 = Acceleration
Ramp dec state Ramp state. 1 = Deceleration
Ramp out != 0 Ramp output different from zero. If enable = 0. If disable = 1
Ramp cmds mon Command monitor for the ramp Block
Bit 0 -> Ramp output = 0, if ONE the value is 1
Bit 1 -> Ramp input = 0, if ONE the value is 2
Bit 2 -> Ramp freeze, if ONE the value is 4
Bit 3 -> Ramp out enable
NOTE!
the acceleration/deceleration state makes reference to a speed increase/decrease with an
absolute value.
Ramp shape
n
t
Figure 1.7.3.1: Ramp Shape