458 Programming: Special Functions
11.11 Defining coordinate transformations
TRANS DATUM TABLE
You can define a datum shift by selecting a datum number from a
datum table with the TRANS DATUM TABLE function. Proceed as follows
for the definition:
Show the soft-key row with special functions
Select the menu for defining various plain-language
functions
Select transformations
Select datum shifting with TRANS DATUM
Select datum shifting with TRANS DATUM TABLE
Enter the line number to be activated by the TNC, and
confirm with the ENT key
If desired, enter the name of the datum table from
which you want to activate the datum number, and
confirm with the ENT key. If you do not want to define
a datum table, confirm with the NO ENT key
Beispiel: NC block
13 TRANS DATUM TABLE TABLINE25
If you have selected a datum table in the TRANS DATUM
TABLE block, then the TNC uses the programmed line
number only until the next call of a datum number
(blockwise effective datum shift).
If you did not define a table in the TRANS DATUM TABLE
block, then the TNC uses the datum table already selected
in the NC program with SEL TABLE or the datum table with
status M selected in one of the Program Run modes.

Table of Contents

Other manuals for HEIDENHAIN ITNC 530

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HEIDENHAIN ITNC 530 and is the answer not in the manual?

HEIDENHAIN ITNC 530 Specifications

General IconGeneral
BrandHEIDENHAIN
ModelITNC 530
CategoryControl Systems
LanguageEnglish

Related product manuals