EasyManuals Logo

HEIDENHAIN ITNC 530 User Manual

HEIDENHAIN ITNC 530
745 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #480 background image
480 Programming: Special Functions
11.15 Freely definable tables
FN 28: TABREAD: Reading a freely definable
table
After you have opened a table with FN 28: TABREAD, you can use the
function FN 26: TABOPEN to read from it.
You can define, i.e. read in, up to 8 column names in a TABREAD
block. The column names must be written between quotation marks
and separated by a comma. In the FN 28 block you can define the Q
parameter number in which the TNC is to write the value that is first
read.
Example:
You wish to read the values of the columns “Radius,” “Depth” and
“D” from line 6 of the presently opened table. Save the first value in
Q parameter Q10 (second value in Q11, third value in Q12).
You can read only numerical table fields.
If you wish to read from more than one column in a block,
the TNC will save the values under successive Q
parameter numbers.
56 FN 28: TABREAD Q10 = 6/“RADIUS,DEPTH,D“

Table of Contents

Other manuals for HEIDENHAIN ITNC 530

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HEIDENHAIN ITNC 530 and is the answer not in the manual?

HEIDENHAIN ITNC 530 Specifications

General IconGeneral
Control TypeCNC
Look-aheadYes
Spindle controlYes
Touch probe cyclesYes
Operating voltage24 V DC
ProgrammingConversational and DIN/ISO programming
InterpolationLinear, Circular, Helical
Data InterfaceEthernet, USB, RS-232
Memory1 GB
Programming LanguageHEIDENHAIN plain language
Operating ModesManual, Automatic, MDA
Software OptionsVarious software options available