14.9 Workpiece presetting with a touch probe
Corner as preset—using points that were
already probed for a basic rotation
Select the touch probe function: Press the PROBING
P soft key
Touch points of basic rotation ?: Pressing the ENT
key to transfer the touch point coordinates to
memory
Position the touch probe at a position near the first
touch point of the side that was not probed for basic
rotation
Select the probe direction by soft key
Start the probing procedure: Press the NC Start button
Position the touch probe near the second touch point
on the same workpiece edge
Start the probing procedure: Press the NC Start button
Datum: Enter both coordinates of the datum in the
menu window, confirm with the SET DATUM soft
key, or write the values to a table (see "Writing the
measured values from touch probe cycles to datum
tables", page 597, or see "Writing the measured
values from touch probe cycles in the preset table",
page 598, or see "Storing measured values in the
pallet preset table", page 598)
To terminate the probe function, press the END key
Corner as datum—without using points that
were already probed for a basic rotation
Select the touch probe function: Press the PROBING P soft key
Touch points of basic rotation ?: Press the NO ENT key to ignore
the previous touch points. (The dialog question only appears if a
basic rotation was made previously.)
Probe both workpiece edges twice
Datum: Enter the coordinates of the datum and confirm your entry
with the SET DATUM soft key, or write the values to a table (see
"Writing the measured values from touch probe cycles to datum
tables", page 597, or see "Writing the measured values from touch
probe cycles in the preset table", page 598, or see "Storing
measured values in the pallet preset table", page 598)
To terminate the probe function, press the END key
P
X=?
Y=?
X
Y
P
X
Y

Table of Contents

Other manuals for HEIDENHAIN ITNC 530

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HEIDENHAIN ITNC 530 and is the answer not in the manual?

HEIDENHAIN ITNC 530 Specifications

General IconGeneral
BrandHEIDENHAIN
ModelITNC 530
CategoryControl Systems
LanguageEnglish

Related product manuals