• TCP Windows size
• TCP Windows scaling factor
• Use the recommended setting documented in this guide for the actual bandwidth and RTT of
the link
• Software compression
• Enable compression for IP links with round-trip time (RTT) >= 50 milliseconds or a guaranteed
WAN bandwidth <= 155 Mb/s.
NOTE:
HP recommends that you accept the default settings for TCP Port and GE Port Speed. If you need to
change the port speed, select Full Duplex mode; Half Duplex mode is not supported.
Configure the FCIP routes using the CLI
For each MPX200, configure the FCIP route information as shown in Figure 76:
Figure 76 Configuring the FCIP routes using the CLI
.
Step 7. Configure FC switch settings for the MPX200
Execute the following commands for all B-series FC switches that will use the FCIP link:
• B-Switch# switchdisable
• B-Switch# iodset
• B-Switch#aptpolicy 1
• B-Switch#portcfgIslmode [
slot/ port
], 1 (Must be set for all MPX200 FCIP FC ports regardless
of storage types)
• B-Switch# portcfggport [
slot/ port
] ,1 (set for all MPX200 FCIP FC ports)
• B-Switch# switchenable
For C-series FC switches, execute the following commands for each VSAN that will use the FCIP link.
Enter one command per line.
• C-Switch# config
MPX200 FCIP124