EasyManuals Logo
Home>HP>Storage>StorageWorks 6100 - Enterprise Virtual Array

HP StorageWorks 6100 - Enterprise Virtual Array User Manual

HP StorageWorks 6100 - Enterprise Virtual Array
362 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #172 background imageLoading...
Page #172 background image
Show LUNinfo
Displays detailed information for a specified LUN and target.
NoneAuthority
show luninfo
Syntax
Example:
MPX200 <1>(admin) #> show luninfo
0 50:00:1f:e1:50:07:0c:e0,50:00:1f:e1:50:07:0c:e9
1 50:00:1f:e1:50:07:0c:e0,50:00:1f:e1:50:07:0c:ec
Please select a Target from the list above ('q' to quit): 0
Index (LUN/VpGroup)
----- ------
0 0/VPGROUP_1
1 1/VPGROUP_1
Please select a LUN from the list above ('q' to quit): 1
LUN Information
-----------------
WWULN 50:00:1f:e1:50:07:0c:e0
LUN Number 0
VendorId HP
ProductId HSV210
ProdRevLevel 5000
Portal 1
Lun Size 0 MB
Lun State Online
Show LUNs
Displays LUN information for each target.
NoneAuthority
show luns
Syntax
Example:
MPX200 <1>#> show luns
Target(WWPN) VpGroup LUN
============ ======= ===
50:00:1f:e1:50:07:0c:e9 VPGROUP_1 0
VPGROUP_1 0
VPGROUP_1 1
VPGROUP_1 2
VPGROUP_1 3
50:00:1f:e1:50:07:0c:ec VPGROUP_2 0
VPGROUP_2 0
VPGROUP_2 1
Command referencecommand reference172

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks 6100 - Enterprise Virtual Array and is the answer not in the manual?

HP StorageWorks 6100 - Enterprise Virtual Array Specifications

General IconGeneral
BrandHP
ModelStorageWorks 6100 - Enterprise Virtual Array
CategoryStorage
LanguageEnglish

Related product manuals