Configuration
Configuring MotionBus/system bus (CAN)
Setting of boot−up time/cycle time
8
176
EDBCSXS064 EN 4.0
8.1.4 Setting of boot−up time/cycle time
Boot−up time (C0356/1) setting
In a CAN network without higher−level control (PLC), a bus node (boot−up master) has to
initialise the CAN network. If the 24 V low−voltage supply is switched on, the boot−up time
elapses. After the boot−up time has elapsed, the NMT telegram for initialising the CAN
network is sent by the boot−up master and the process data transfer is started.
ƒ Only valid if C0352 = 1 (master).
ƒ Normally the Lenze setting (3000 ms) is sufficient.
ƒ State change from "Pre−operational" to "Operational"
Cycle time for process output data (C0356/2...3)
Transmission cycle time for the process data objects CAN2...3_OUT (C0356/2...3) in cyclic
operation (without sync)
ƒ Setting "0" = event−controlled data transmission
The output data will only be sent if a value in the output object changes.
Activation delay for process output data (C0356/4)
Delay time for initial transmission of the process data objects CAN2...3_OUT after the CAN
bus changed from "Pre−Operational" to "Operational" NMT state.
After the delay time has elapsed, the process data objects CAN2...3_OUT or
CANaux2...3_OUT will be sent for the first time.

Table of Contents

Other manuals for Lenze ECSES Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze ECSES Series and is the answer not in the manual?

Lenze ECSES Series Specifications

General IconGeneral
BrandLenze
ModelECSES Series
CategoryControl Unit
LanguageEnglish

Related product manuals