Technical Information
80
CVA 4062/CVA 4066/CVA 4068 Coffee Systems
Note:
The approximate resistance values of this NTC are
100k at 77°F (25°C),
5.5k at 212°F (100°C), and
1k at 320°F (160°C).
4. Check the resistance of the temperature sensor at different temperatures and
compare to the above values.
5. Replace the temperature sensor, if necessary.
3.3 F3 -- Steam NTC (1R30) Short-Circuited
Cause:
Steam NTC (1R30) short-circuited.
Remedy:
1. Check the connection leads.
2. Replace the connection leads, if necessary.
3. Check the temperature sensor via service mode.
Note:
The approximate resistance values of this NTC are
100k at 77°F (25°C),
5.5k at 212°F (100°C), and
1k at 320°F (160°C).
4. Check the resistance of the temperature sensor at different temperatures and
compare to the above values.
5. Replace the temperature sensor, if necessary.
3.4 F4 -- Steam NTC (1R30) Open-Circuited
Cause:
Steam NTC (1R30) open-circuited.
Remedy:
1. Check the connection leads.
2. Replace the connection leads, if necessary.
3. Check the temperature sensor via service mode.
Note:
The approximate resistance values of this NTC are
100k at 77°F (25°C),
5.5k at 212°F (100°C), and
1k at 320°F (160°C).
4. Check the resistance of the temperature sensor at different temperatures and
compare to the above values.
5. Replace the temperature sensor, if necessary.

Table of Contents

Other manuals for Miele CVA 4062

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Miele CVA 4062 and is the answer not in the manual?

Miele CVA 4062 Specifications

General IconGeneral
BrandMiele
ModelCVA 4062
CategoryCoffee Maker
LanguageEnglish

Related product manuals