CVA 4062/CVA 4066/CVA 4068 Coffee Systems
Cause:
Hose connections interrupted, blocked or kinked.
Remedy:
1. Check hose connections.
2. Replace hoses, if necessary.
Cause:
Water container valve jammed or clogged.
Remedy:
1. Check water container valve.
2. Replace water container, if necessary.
Cause:
Flow meter (B3/4) defective or clogged.
Remedy:
1. Install a new flow meter. See Flow Meter (B3/4) Removal, Section 051-4.5.
Cause:
Coffee/hot water pump (2M7) defective.
Remedy:
1. Install a new coffee/hot water pump. See Coffee/Hot Water Pump Removal,
Section 051-4.3.
Cause:
Water paths need to be descaled.
Remedy:
1. Descale the appliance; see the operating instructions.
2. Replace the coffee/hot-water heater, including the brew unit
hose and spout.
Cause:
Brew unit jammed.
Remedy:
Follow the remedy procedure outlined in F73 -- Brew Unit Fault (Page 83).
Warning!
In order to avoid possible water system faults (e.g., clogging or blocking of valves),
grease, oil or other slip lubricants should never be used when assembling and
installing water system parts.
3.7 F28 -- Too Much Ground Coffee in Brew Unit
Cause:
Excessive ground coffee was taken in through the funnel.
Remedy:
1. Remove the ground coffee.
2. Advise the customer about correct dispensing amounts as outlined
in the operating instructions.

Table of Contents

Other manuals for Miele CVA 4062

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Miele CVA 4062 and is the answer not in the manual?

Miele CVA 4062 Specifications

General IconGeneral
BrandMiele
ModelCVA 4062
CategoryCoffee Maker
LanguageEnglish

Related product manuals