10.15
Battery and Electrical Systems
10
6. After the reset passcode process is complete, the
following screen will be displayed. Click on the
RETURN button to return to the main screen.
7. Cycle the power to the ECU and DC PWR test
con
nectors to finish the procedure.
Security System: Instrument Cluster
Initialization
NOTE: Use the MODE button on the cluster when
performing procedure on models featuring the
analog/digital instrument cluster.
Instrument cluster initialization is a on
e-time procedure
that must be performed when the instrument cluster is
linked for the first time to a security-enabled ECU.
The ECU and instrument cluster
must be powered at the
same time. This is accomplished with the chassis power-
up harness and dual power-up adapter.
When using the chassis power-up harness and dual
po
wer-up adapter, follow these steps:
1. Open the left side engine compartment door and
lo
cate the Digital Wrench® diagnostic plug, ECU
power plug, and DC PWR test plug.
2. Connect the dual power-up adapter to the chassis
po
wer-up harness. Attach one of the dual power-up
connectors to the ECM PWR plug and the other
connector to the DC PWR TEST plug. Connect the
alligator clamps to a fully charged 12 VDC battery.
NOTE: The ECU and DC chassis power circuits
(
instrument cluster, LED brake, etc) are now powered.
Confirm the instrument cluster is powered-up.
3. Hold the brake lever. Pr
ess and hold the MODE and
SEL buttons for 3 seconds, then release. SECURE
OFF should be displayed. If not, repeat this step.