3. Increase the value by 0.2 mm.
4. Print the image. Is the problem resolved?
Yes Finished!
No Repeat Step 2 to 4. If the problem persists even though you have increased the value
to 4 mm, contact your service representative.
Z-Folding is Not Performed Properly
Cause:
If a sheet is curled and its edge touches the guide board, proper folding may not be possible.
Paper feed direction
Upward curl (radius 4 cm [1.6 in.] or less)
on the leading edge of delivered paper.
DFP800
Solution:
1. In the [Main Unit: Paper Feed/ Output] group on the [Adjustment Settings for Operators]
menu, set 0310: [Correct Output Paper Curl] to [U Curl Correction Level: Small].
2. Print the image. Is the problem resolved?
Yes Finished!
No Go to the next step.
3. Load the paper the other way up.
4. Print the image. Is the problem resolved?
Yes Finished!
No Contact your service representative.
5. Post-Processing Option Troubleshooting
164