SC Code List
This table contains a list of selected SC codes. If the SC code that is displayed on the control panel is
listed in this table, carry out the recommended procedure. If the SC Code is not listed in this table,
contact your service representative.
• If the error persists after replacing the unit, contact your service representative.
Code Error Procedure
332-01 Toner supply motor 1 error (left bottle) Check that toner supply motor 1 operates
properly.
332-05 Toner supply motor 2 error (right bottle) Check that toner supply motor 2 operates
properly.
336-01 Developer imperfect setting (K) Check the developer.
410-01 Remaining potential: Vr detection error (K) Replace the photoconductor unit.
411-01 Charge potential: Vd adjustment error (K) Replace the charge unit.
412-01 Exposure potential: Vpl adjustment error (K) Replace the charge unit.
2. Troubleshooting Service Call Problems (SC Codes)