USO RESTRITO
Interfacing with External Devices 365
Chapter
20
DME
Setup
When Target is Ch1 or Ch2: Aspect, No Action
When Target is Proc: Format
1)
, Aspect, Level Enable,
No Action
For details about “Level Enable, see “Notes” in
“Making Control Panel GPI Input Settings
(
1
p. 337).
1)
Cannot be selected on DME1.
Carrying out level settings
To set the low level and high level, first set the trigger type
to “Level,” then use the following procedure.
1
In the Engineering Setup >DME >Device Interface
>DME1 GPI Input menu (7344.1), select the action to
be set, and press [H/L Set].
The H/L Set menu (7344.2) appears.
2
Select the setting.
3
To apply the selection made in step 2 when the input
is the GPI high level, press [H Set]. To apply the
selection the input is low, press [L Set].
Making DME GPI Output Settings
This sets the GPI output ports and trigger type, and makes
the action settings.
Notes
There is no GPI output in DME1.
1
Open the Engineering Setup >DME >Device Interface
>DME2 GPI Output menu (7344.6).
The output port selection is fixed at 1.
2
In the <Trigger Type> group, select the trigger type.
Status: Depending on the status, the relay contacts are
closed or opened, or the output is switched
between high and low.
No Operation: The trigger has no effect on the relay
state or output level.
3
Select the action to be set.
4
Press [Action Set] to confirm the action selection.

Table of Contents

Other manuals for Sony MVS-6530

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sony MVS-6530 and is the answer not in the manual?

Sony MVS-6530 Specifications

General IconGeneral
BNC input ports48
BNC output ports32
RJ-45 input ports4
Product colorBlack
AC input voltage100 - 240 V
AC adapter frequency50/60 Hz
AC adapter input current4 A
Storage temperature (T-T)-20 - 55 °C
Operating temperature (T-T)5 - 40 °C
Weight and Dimensions IconWeight and Dimensions
Depth486 mm
Width482 mm
Height176 mm
Weight21000 g

Related product manuals