6-4 EXHAUST SYSTEM
INSPECTION
Inspect the exhaust pipe connection and muffler connection for exhaust gas leakage and mounting condi-
tion. If any defect is found, replace the exhaust pipe or muffler with a new one.
Check the exhaust pipe bolts, muffler connecting bolt and muffler mounting bolts are tightened to their spec-
ified torque.
Exhaust pipe bolt 1: 23 N·m (2.3 kgf-m, 16.5 lbf-ft)
Muffler connecting bolt 2: 23 N·m (2.3 kgf-m, 16.5 lbf-ft)
Muffler mounting bolt (Front) 3: 23 N·m (2.3 kgf-m, 16.5 lbf-ft)
Muffler mounting bolt (Rear) 4: 50 N·m (5.0 kgf-m, 36.0 lbf-ft)
INSTALLATION
Installation is in the reverse order of removal.
Pay attention to the following points:
• Tighten the HO2 sensor 1 to the specified torque.
HO2 sensor: 25 N·m (2.5 kgf-m, 18.0 lbf-ft)
Do not apply oil or other materials to the HO2 sensor
air holes.