MP-3000 Controller
58
21. Display menus: The MPC-3000 controller
contains an extensive display menu that can be
navigated via keypad. The display menu is
organized into eight main menus:
NOTE: The screens that display on the
controller are determined by the controller
software setting and the options installed on
the unit. All screens are NOT present on all
units.
Setpoint Menu: Menu screens in this
group are used to enter the temperature
setpoint and set the Economy mode.
Setpoint menu option functions include:
set Bulb mode, set air flow, set Delta T, set
humidify or dehumidify operation and
enter humidity setpoint, set AFAM, set
AFAM delay, set AFAM rate, set O
2
Minimum and set CO
2
Maximum.
Data Menu: Menu screens in this group
are used to display unit operating
information including sensor
temperatures, voltage, current and
frequency information.
Alarm List Menu: Menu screens in this
group display a list of alarm code(s).
Commands Menu: Menu screens in this
group are used to activate pre-trip (PTI)
tests, function tests, manual function tests,
and power management.
Miscellaneous Functions Menu: Menu
screens in this group display date/time,
C/F, cargo data, program version and run
time (hourmeters) information.
Configuration Menu: Menu screens in this
group display refrigerant type, in-range
setting, container ID, contrast (screen),
language, unit type, reefer type, zero
current status, AFAM option, evaporator
type, condenser type, USDA type, VFD
minimum frequency, VFD maximum
frequency, AFAM units and other unit
settings.
Data logger Menu: Menu screens in this
group display temperature log, event log,
set log time and PTI log.
REFCON Remote Monitoring (RMM)
State: Menu screen show current remote
monitoring state (Offline, Zombie or
On-line).
22. Active option display: The MP-3000
controller shows a list of active control
options in left side of the LCD display.
Options that may appear in the display include
Bulb mode, Economy mode, Humidify mode
and Dehumidify mode.
Status Indicator LEDs
Eight status indicator LEDs are located in the top
LED display and signal the following:
Supply (Air Temperature)
Return (Air Temperature)
Humidity Mode (Humidification set to On in
Setpoint menu)
Compressor (Cooling On)
Heat (On)
Defrost
In-range (Temperature)
Alarm
The indicator LEDs stay on continuously to
indicate sensor temperature display, unit operating
mode or condition.
The Alarm LED flashes on and off continuously
when a Check Alarm (Level 2 Alarm) or
Shutdown Alarm (Level 1 Alarm) occurs. Less
serious Log Alarms (Level 3 Alarm) are recorded
but do not activate the Alarm LED (see Alarms
Menu on 78 for more information).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thermo King CSR Series and is the answer not in the manual?

Thermo King CSR Series Specifications

General IconGeneral
BrandThermo King
ModelCSR Series
CategoryRefrigerator
LanguageEnglish

Related product manuals