MP-3000 Controller
94
•“LANGUAGE: English is only setting
currently available.
•“ECONOMY MAX: Sets the Economy
mode maximum temperature limit (factory
default = 0.2 C). Enter a value from 0 to
5.0 C (0 to 8.9 F).
•“ECONOMY MIN: Sets the Economy
mode minimum temperature limit (factory
default = 2.0 C). Enter a value from 0 to
5.0 C (0 to 8.9 F).
•“UNIT TYPE: View display value
(factory default = NO HUM). Controller
automatically activates when a humidity
sensor is installed for more than 1 minute.
Setting this value is not necessary.
•“DEHUMIDIFICATION VALVE
•“REEFER TYPE: Sets the unit model
state to CSR20SL PS or CSR40SL
PS/CSR40 PS. Must be manually set to
unit type on unit serial number plate.
•“ZERO CURRENT: View display on or
off value (factory default = on). However,
no errors occur if a Zero Current
transformer is not installed and
configuration is set to on.
•“SUPPLY LH: View display on or off
value (factory default = off). Controller
automatically activates when a left hand
supply sensor is installed for more than 1
minute. Setting this value is not necessary.
•“AFAM OPTION: Sets the Advanced
Fresh Air Management System to None,
AFAM, AFAM+ or Analyzer (factory
default = None). Controller automatically
activates when an AFAM system vent
door and/or AFAM+ gas sensor is installed
for more than one minute. Setting this
value is not necessary. However, to
calibrate the gas sensor unit, the container
must be opened and aired out for at least
15 minutes. Then close container doors
and manually set AFAM Option to
Analyzer. Analyzer turns on data logging
of gas sensor readings only.
•“EVAPORATOR TYPE: Sets the
evaporator fan value to VFD 2 fan, 3 fan
or 2 fan. Must be manually set.
•“CONDENSER TYPE: Sets the
condenser fan value to 1/2 HP, 2 HP or 3/4
HP. Must be manually set.
•“USDA TYPE: Sets the controller for
3THERM, PT100 or 4THERM type
USDA sensors. Must be manually set to
activate USDA data logging with NTC
(3THERM or 4THERM) type sensors.
•“CHART R: Shows: Not Present, -20 F
to 80 F 31 day, -30 C to +25 C 31 day, -25
C to 25 C 31 day.
•“AFAM UNITS: Sets the AFAM system
units to CF (cubic feet per minute),
M3 (cubic meters per hour) or
PERCENT (default is M3).
•“AUTO CONFIGURATION: View
display on or off value (factory
default = off). Set value to on to
automatically configure unit to installed
components. See Automatic
Configuration of Spare Parts Controller
in this chapter for additional information.
•“UNIT #: Sets the unit serial number.
Enter up to 11 characters (number or
letters). Serial number must be manually
set. Serial number is required to enable
automatic detection of PT100 type USDA
sensors on units with serial numbers
beginning with MAE, MSF or MWC
prefix.
•“UNIT ID: An 11 digital alpha-numeric
container number.
NOTE: Model CSR units without a serial
number beginning with MAE, MSF or MWC
must be set for USDA temperature sensing. See
USDA Type above.
5. To set a new Configuration screen value:
a. Press F4 key with cursor in the desired
menu line. The Password screen appears.
b. Press F2 key, A key (password is A), F4
key and then E
XIT key. An Enter Arrow
appears in the hourmeter line.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thermo King CSR Series and is the answer not in the manual?

Thermo King CSR Series Specifications

General IconGeneral
BrandThermo King
ModelCSR Series
CategoryRefrigerator
LanguageEnglish

Related product manuals