MP-3000 Controller
99
Set Log Time
With the UNIT ON/OFF switch ON and the LCD
display showing the standard display (setpoint):
1. Press F3 key to enter the Main menu.
2. Press F3 key to scroll through the menu list
until “DATALOGGER” appears in LCD
display.
3. Press F4 key to access the Datalogger menu.
“INSPECT TEMP LOG” appears in the LCD
display.
4. Press F2 or F3 key to scroll through submenu
until “SET LOG TIME” appears in LCD
display.
5. Press F4 key to enter Temp Log. LCD display
shows the current Log Time interval.
6. To enter a new log interval, press F4 key
again with cursor in “LOG TIME” menu line.
“ARROW” appears in menu line.
7. Press F3 key to scroll through a list of log
time intervals:
•“1 MINUTE”*
•“1/2 HOUR”
•“1 HOUR”
•“2 HOUR”
•“4 HOUR”
8. When the correct Log Time appears in the
menu line, press and hold F4 key until cursor
stops flashing. The new Log Time appears in
the display.
9. Press ESC key to exit the Temp Log.
Set a Trip Start
With the UNIT ON/OFF switch ON and the LCD
display showing the standard display (setpoint):
1. Press F2 key to enter the menu list.
Repeatedly press F2 key to scroll through
Main menu until “DATALOGGER” appears
in LCD display.
2. Press F4 key to access the Datalogger menu.
“INSPECT TEMP LOG” appears in the LCD
display.
3. Press F2 or F3 key to scroll through submenu
until “ACTIVATE TRIPSTART” appears in
LCD display.
4. Press F4 key to enter Tripstart function. The
date and time of the last trip start appears in
the screen.
5. Press F4 key again to enter a new start of trip
date and time in the log.
NOTE: When a PTI test is completed, the
controller automatically enters a Tripstart in
the log.
6. Press ESC key to exit the Datalogger menu.
Inspect Event Log
With the UNIT ON/OFF switch ON and the LCD
display showing the standard display (setpoint):
1. Press F3 key to enter Main menu.
2. Press F3 key to scroll through Main menu
until “DATALOGGER” appears in LCD
display.
3. Press F4 key to access the Datalogger menu.
“INSPECT TEMP LOG” appears in the LCD
display.
4. Press F2 or F3 key to scroll through submenu
until “INSPECT EVENT LOG” appears in
LCD display.
5. Press F4 key to enter Event Log. LCD display
shows the Log Time and the most recent
event.
• To scroll through previous event log
screens, press F3 key. All event logs
recorded in the datalogger memory may be
viewed on the LCD display.
Event Examples
• Controller alarm status (alarms set/cleared)
• Main power On/Off status (humidity On/Off,
temperature setpoint, and main power Hz)
• 12 Vdc battery discharge test (battery voltage,
total unit and compressor hours if main power
on) — this event logged at once a day
• Change temperature setpoint (new/old
setpoint)
• Change RH setpoint (new/old RH setpoint)