Startup Procedure and Test Run
4
4.7 Keypad Operation
YASKAWA SIEPC71061753C GA500 Technical Manual 139
Figure 4.19 How to Change the Parameter Setting
Continue to change parameters or push and hold to go back to the frequency reference screen.
Save a Backup of Parameters
Show the frequency reference screen in advance.
Note:
Push and hold to go back to the frequency reference screen from any screen.
Use these steps to save a backup of the drive parameters to the keypad.
Making backups of the parameter settings can save time when setting parameters after replacing a drive. If you set
up more than one drive, you can copy the parameter settings from a drive that completed a test run to the other
drives.
Note:
Make sure that you stop the motor before you back up parameters.
The drive does not accept Run commands while it is making a backup.
Set o3-02 = 0 [Copy Allowed Selection = Disabled] to protect the parameters saved in the keypad.
Figure 4.20 How to Save Backed-up Parameters
Push and hold to go back to the frequency reference screen.

Table of Contents

Other manuals for YASKAWA CIPR-GA50C series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA CIPR-GA50C series and is the answer not in the manual?

YASKAWA CIPR-GA50C series Specifications

General IconGeneral
BrandYASKAWA
ModelCIPR-GA50C series
CategoryController
LanguageEnglish

Related product manuals