Specifications
10
10.6 Drive Specifications
YASKAWA SIEPC71061753C GA500 Technical Manual 337
10.6 Drive Specifications
Note:
To get the OLV specifications, do Rotational Auto-Tuning.
To get the longest product life, install the drive in an environment that meets the necessary specifications.
Table 10.9 Control Characteristics
Item Specification
Control Methods
V/f Control
Open Loop Vector
PM Open Loop Vector
PM Advanced Open Loop Vector
EZ Vector Control
Frequency Control
Range
V/f, OLV, and OLV/PM: 0.01 Hz to 590 Hz
AOLV/PM: 0.01 Hz to 270 Hz
EZOLV: 0.01 Hz to 120 Hz
Frequency Accuracy
(Temperature
Fluctuation)
Digital inputs: ±0.01% of the maximum output frequency (-10 °C to +40 °C (14 °F to 104 °F))
Analog inputs: In ±0.1% of the maximum output frequency (25 °C ±10 °C (77 °F ±18 °F))
Frequency Setting
Resolution
Digital inputs: 0.01 Hz
Analog inputs: 1/2048 of the maximum output frequency (11-bit)
Output Frequency
Resolution
0.001 Hz
Frequency Setting
Signal
Main speed frequency reference: 0 Vdc to 10 Vdc (20 kΩ), 4 mA to 20 mA (250 Ω), 0 mA to 20 mA (250 Ω)
Main speed reference: Pulse train input (maximum 32 kHz)
Starting Torque
V/f: 150%/3 Hz
OLV: 150%/1 Hz
OLV/PM: 100%/5% speed
AOLV/PM: 100%/0 min
-1
(when high frequency injection is enabled)
EZOLV: 100%/10% speed
Note:
Correctly select the drive and motor capacity for this starting torque in these control methods:
OLV
AOLV/PM
Speed Control Range
V/f: 1:40
OLV: 1:100
OLV/PM: 1:10
AOLV/PM: 1:100 (when high frequency injection is enabled)
EZOLV: 1:10
Zero Speed Control
Possible in AOLV/PM control methods.
Torque Limits
You can use parameter settings for different limits in four quadrants in these control methods:
OLV
AOLV/PM
EZOLV
Acceleration and
Deceleration Times
0.0 s to 6000.0 s
The drive can set four pairs of different acceleration and deceleration times.
Braking Torque
Approximately 20% without a resistor
Approximately 125% with a dynamic braking option
Short-time average deceleration torque
Motor output 0.1/0.2 kW: over 150%
Motor output 0.4/0.75 kW: over 100%
Motor output 1.5 kW: over 50%
Motor output 2.2 kW and larger: over 20%, Overexcitation Braking/High Slip Braking allow for approximately 40%
WARNING!
Set L3-04 = 0 [Stall Prevention during Decel = Disabled] when you operate the drive with:
a regenerative converter
regenerative unit
braking resistor
braking resistor unit.
If you set the parameter incorrectly, the drive can decelerate for too long and cause serious injury or death.
Note:
Short-time average deceleration torque refers to the necessary torque to decelerate the motor (uncoupled from the load) from the rated speed to zero.
Motor characteristics can change the actual specifications.
Motor characteristics change the continuous regenerative torque and short-time average deceleration torque for motors 2.2 kW and larger.

Table of Contents

Other manuals for YASKAWA CIPR-GA50C series